Growatt Inverter Error Codes

Experiencing issues with your Growatt inverter can be challenging. Understanding the specific error codes can help in diagnosing and resolving problems efficiently. Below is a comprehensive guide to common Growatt inverter error codes and their corresponding solutions.

Growatt solar inverter error code isolation fault

Growatt Inverter Error Code: No AC Connection

Description: No utility grid detected or utility grid power failure.

Solution: This error typically occurs during a grid failure. If your property still has power, check your AC isolator or circuit breaker. If both are 'on' and the problem persists, submit a maintenance service request.

Growatt Inverter Error Code: AC V Outrange

Description: Utility grid voltage is out of permissible range.

Solution: This could happen, particularly in the summer months if there is a lot of solar in your area. If the problem persists, please submit a maintenance service request.

Growatt Inverter Error Code: AC F Outrange

Description: Utility grid frequency is out of range.

Solution: Similar to the AC voltage issue, this can occur during periods of high solar activity. If the problem persists, please submit a maintenance service request.

Growatt Inverter Error Code: Over Temperature

Description: Temperature out of range.

Solution: Restart the inverter. If the error persists, contact Growatt. Ensure the inverter is not covered or placed in direct sunlight, causing it to overheat.

Growatt Inverter Error Code: PV Isolation Low

Description: Insulation problem detected.

Solution: Submit a maintenance service request to have the insulation inspected and repaired as necessary.

Growatt solar inverter error code 117

Growatt Inverter Error Code: Output High DCI

Description: Output current DC offset too high.

Solution: Restart the inverter. If the problem persists, submit a maintenance service request.

Growatt Inverter Error Code: Residual 1 High

Description: Leakage current too high.

Solution: Restart the inverter. If the problem persists, submit a maintenance service request.

Growatt Inverter Error Code: PV Voltage High

Description: DC input voltage is exceeding the maximum tolerable value.

Solution: Disconnect the DC switch immediately and switch off the system. Submit a maintenance service request.

Growatt Inverter Error Code: Auto Test Failed

Description: Automatic test sequence has failed.

Solution: Restart the inverter; the fault should clear. If it persists, contact Growatt support.

Growatt Inverter Error Code: 100

Description: Voltage fault detected.

Solution: Submit a maintenance service request to diagnose and resolve the voltage issue.

Growatt solar inverter error code front left view

Growatt Inverter Error Code: 101

Description: Communication fault.

Solution: Turn off the DC switch and allow the inverter to shut down completely. Turn on the DC switch to see if the error still exists. If the error persists, submit a maintenance service request.

Growatt Inverter Error Code: 102

Description: Consistent fault; data received by master and slave processors are different.

Solution: Follow the same steps as for Error 101. If unresolved, submit a maintenance request.

Growatt Inverter Error Code: 116

Description: EEPROM fault; failure in reading or writing EEPROM.

Solution: If the error appears only in the morning, contact Growatt support. If it occurs all day, restart the inverter. If the fault remains, the control board may need replacement. Submit a maintenance request.

Growatt solar inverter error code on a 12kw off grid

Growatt Inverter Error Code: 117

Description: Relay circuit malfunction.

Solution: Restart the inverter. If the problem persists, request maintenance.

Growatt Inverter Error Code: 118

Description: Initialization mode fault.

Solution: Submit a maintenance service request for further diagnosis and repair.

Growatt Inverter Error Code: 119

Description: GCFI device damage; potential issue with the Ground Fault Circuit Interrupter.

Solution: Restart the inverter 2-3 times. If the error persists, submit a maintenance request.

Growatt Inverter Error Code: 120

Description: HCT fault; issue with the current sensor.

Solution: Restart the inverter. If the issue continues, request maintenance.

Growatt Inverter Error Code: 121

Description: Communication failure; master processor not receiving data from the slave processor.

Solution: See troubleshooting steps for Errors 101 and 102. If unresolved, submit a maintenance request.

Request a quote from Solair Electrical